
Exceptional Food & Beverage Innovations

Innovative Chemical Solutions

Quality and Genetic

Revolutionizing Plant and Medical Research

Milk Plants in Dairy Production

Key Techniques and Discoveries

Revolutionizing Wastewater Treatment

Holistic Healing Through Science

Innovative Pharmaceutical Solutions

Evolution and Innovation

Driving Innovation and Technological

Leading Hospital Laboratory Services

Precision and Accuracy

Pioneering Hope in Fertility Treatments

Pioneering Biotech Innovations

Shaping the Future of Learning

Lab Comforts

Testing before packaging

Impact and Innovations
Manufacturer & Exporters of Laboratory Testing Instruments

Exceptional Food & Beverage Innovations

Innovative Chemical Solutions

Quality and Genetic

Revolutionizing Plant and Medical Research

Milk Plants in Dairy Production

Key Techniques and Discoveries

Revolutionizing Wastewater Treatment

Holistic Healing Through Science

Innovative Pharmaceutical Solutions

Evolution and Innovation

Driving Innovation and Technological

Leading Hospital Laboratory Services

Precision and Accuracy

Pioneering Hope in Fertility Treatments

Pioneering Biotech Innovations

Shaping the Future of Learning

Lab Comforts

Testing before packaging

Impact and Innovations
Manufacturer & Exporters of Laboratory Testing Instruments
Electrically Heated model with voltage Variac for control. Suitable for determination of closed cup flash point determination of Petroleum and petroleum products having flash points below 70ºC. Optional : Digital temperature indicator Electrically Driver Stirrer with a FHP Motor having flexible shaft Oil Cup Thermometer (-35ºC to 70ºC) Water Bath Thermometer (-30ºC to 80ºC) Also Looks for PENSKY MARTIN FLASH POINT APPARATUS
(Direct Reading of CALORIFIC VALVE with Printer) BOMB IS MADE OF SS 316 Temp. Accuracy ± 0.001˚C Display of Direct Reading of CALORIFIC VALVE with thermal printer Menu driven settings for parameters LCD display Buzzer based alarm facility Memory storage for input data in software Erroneous messages displayed in case of Fuse wire open No paper and Printer door open indicator. USB interface with PC through software Along with all essential accessories (As per details above) for operation of bomb calorimeter. Optional: Automatic Gas Filling System Oxygen Cylinder Also Looks for DIGITAL BOMB CALORIMETER
BOMB IS MADE OF SS 316 Temp. Accuracy ± 0.01˚C Bomb Calorimeter outfit provides a simple and inexpensive method for determination of heat of combustion of organic matter and the calorific value of solid & liquid fuel. The outfit supplied is complete for analysis as per the method recommended by British standard institution BS 1016. All parts of the outfit have been finished of petroleum and British Standard Institute. Optional: Automatic Gas Filling System Oxygen Cylinder Also Looks for AUTOMATIC BOMB CALORIMETER
Double wall construction, all the electrical and optional accessories inside the chamber will be in between the first and second wall. Interiors acid resistant material coated with fire proof epoxy paint. Working table is covered with Granite Front door is made of 6mm clear Toughened glass. Counter weight balance Front Door. Vertical sliding facility & the front door can be stopped at any point. Exhaust blower consists of single phase motor connected with a PVC Exhaust Ducting. Standard ducting upto 6’ is provided. OR ANY NON STANDARD SIZE. Optional: Base storage cabinet. P.P. Sink with Swan Neck Water Tap Air flow monitor (LCD Display). Automatic motorised front door lifting arrangement. Touch Screen Display with Air Flow Monitor. Scrubber System Also Looks for FUME HOOD (SINGLE WALLED)
Laboratory fume hoods are one of the most important components used to protect laboratory personnel from exposure to hazardous chemicals and agents used in the laboratory. Cabinet is made of : Wooden Body / M.S. Duly Powder Coated / Stainless Steel (304). Interiors acid resistant material coated with fire proof epoxy paint & further fixed on storage cabinet. Working table is covered with Granite Front door is made of 6mm clear Toughened glass. Counter weight balance Front Door. Vertical sliding facility & the front door can be stopped at any point. Exhaust blower consists of single phase motor connected with a PVC Exhaust Ducting. Standard ducting upto 6’ is provided. OR ANY NON STANDARD SIZE. Optional: Base Storage Cabinet P.P. Sink with Swan Neck Water Tap Air flow monitor (LCD Display) Automatic Motorized front door lifting arrangement Touch Screen Display with Air Flow Monitor Scrubber System
Light Weight High Temp. Ceramic Fiber Wool Insulation. Outer Body Double Walled with M.S. Duly Powder Coated / Stainless Steel Body (S.S. 304). Heating Elements are of KHANTHAL “A-1” Wire, Temperature Control Unit Consist of Microprocessor based PID controller (Digital LED Display) fitted in front of Furnace, two pilot lamps & mains On/Off switch. Power plug to work on 220 Volts AC. Optional: Programmable Controller with Ramp & Soak facility (Profile Controller) Microprocessor based Touch Screen Display System 21 CFR Software (For Non Editable Data) Also Looks for HIGH TEMPERATURE FURNACE
Useful for determination of closed cup flash points above 49ºC of fuels, oils, other viscous materials and suspension of solid. Optional : Digital temperature indicator Electrically Driver Stirrer with a FHP Motor having flexible shaft Spare Thermometer (+20ºC to 230ºC) Water Bath Thermometer / Oil Cup Thermometer (+90ºC to 370ºC) for high temp. Also Looks for ABEL’S FLASH POINT APPARATUS